pro series fume hoods
- overview
- details
- options
- resources
- sustainability
- families
standard
versatile, reliable
The Pro Series fume hood has been engineered for both performance and economical savings, making it our most requested fume hood model.
- Stainless steel airfoils
- Durable chain and sprocket sash system
- Available in a variety of configurations
- Special applications include distillation, perchloric acid, and radioisotope
- CAV or VAV
Contact Us!
Face Velocities
- Designed for 80-100 fpm face velocity
-
Tested to ASHRAE-110 Guidelines
Sash Counterbalance System
- Chain and sprocket sash
-
Durable for long lifespan
Viewing Sash
- Provides a clear and unobstructed side-to-side view of the fume hood interior
-
28-1/2” high sash opening
Lower Airfoil
-
Stainless steel lower airfoil
Chemical Resistant Liner
- Standard fiberglass reinforced polyester liner
-
Additional liner materials available
Access Panels
- Interior gasketed access panels
-
Removable exterior side panels for ease of access to plumbing and electrical service fixtures
Duct Collar
-
Bell-shaped Type 316 stainless steel collar
Electrical Services
- Two UL / CSA approved duplex receptacles were provided for 120-volt service
- Built-in LED lighting and a corner post-mounted UL/CSA approved switch provided
-
UL 1805 Classified
Plumbing Services
- The front post is pre-punched to accept up to five plumbing fixtures per side
-
Optional factory pre-plumbing of front-loaded remote fixtures
Fume Hood Types
- Variety of types for special applications (perchloric & radioisotope)
- Bench-mount fume hood
- Floor-mount fume hood
- ADA fume hood
- Distillation fume hood
- Double-sided fume hood
- Demonstration fume hood
-
Custom
* Pro Series fume hood is trademarked and produced by Mott Manufacturing.
Optional Self-Lowering Sash System
- The sash latch temporarily secures the sash in the full open position for setup and tear down
-
When the latch is freed, the sash automatically returns to the operational position
Optional Automatic Sash Closing System
The electronic occupancy sensor system closes the sash automatically when not in use, or within a timed interval when the operator moves away from the fume hood.
Some other commonly requested Pro Series options include:
- Viewing Panels for increased visibility
- Sash Operation Options (Vertical, Horizontal, Combination, Split-Post, etc)
- A Flush sill
Product Brochures |
|||
Title | Size | Download | MyPortfolio |
Mott - Demonstration Fume Hood Brochure | 1.65 mb | [+] | |
Mott - Pro Series Fume Hood | 2.85 mb | [+] | |
NEL - Pro Series Fume Hood Brochure | 1.17 mb | [+] | |
NEL Direct - Rapid Ship Catalog | 3.19 mb | [+] | |
Product Specifications |
|||
Title | Size | Download | MyPortfolio |
Painted Steel Powder Coat Appendix 1 | 15 kb | [+] | |
Pro Series Fume Hood Specifications | 77 kb | [+] | |
Product Manuals |
|||
Title | Size | Download | MyPortfolio |
Fume Hood User and Installation Product Manual | 461 kb | [+] | |
Corporate Literature |
|||
Title | Size | Download | MyPortfolio |
Lab Fume Hood Selector Guide | 745 kb | [+] | |
Catalog Sections |
|||
Title | Size | Download | MyPortfolio |
Mott Fume Hood Catalog Section P | 7.02 mb | [+] | |
Mott Fume Hood Introduction Catalog Pages P1-P3 | 399 kb | [+] | |
Mott Pro Series Fume Hoood Catalog Pages P4-P13, P24-P25, P34-P35 & P40-P57 | 3.20 mb | [+] | |
Rapid Ship Catalog - Fume Hoods & Accessories | 328 kb | [+] |
Our low flow fume hoods can result in considerable energy cost reduction and ensure operator safety. Designed to operate from 60-100 feet per minute face velocities. They have been tested as low as 50 feet per minute.
Our low volume option can result in considerable energy savings by reducing the sash opening size.
An Automatic Sash Operating System can be incorporated that lowers and/or rises automatically which can enhance safety and dramatically increase the efficiency of Variable Air Volume (VAV) fume hood systems.
Steel
Painted steel consists of 85% or greater recycled content:
- 42% post consumer which can contribute to LEED 2.2 credit MR4.1 & M4.2
- 27% pre-consumer which can contribute to LEED 2.2 credit MR4.1 & M4.2
- Systems solutions that maximize mobility and adaptability creating a user friendly, long life-cycle laboratory.
- Durable, high-quality surface protection with minimal waste and Zero VOC's.
- Durability that meets and exceeds SEFA 8 performance standards, to provide an even longer product life cycle.
Stainless steel consists of 90% recycled content:
- 80% post consumer which can contribute to LEED credit MR4
- 20% pre-consumer which can contribute to LEED credit MR4
- Durable, high-quality surface protection with minimal waste and Zero VOC's.
- Durability that meets and exceeds SEFA 8 performance standards, to provide an even longer product life cycle.
pro series - bench-mounted fume hood
The all purpose bench-mounted fume hoods allow work to be done at standing or sitting heights
pro series - floor-mounted fume hood
This all purpose fume hood (formerly called a walk-in) is freestanding and allow for larger items to be wheeled in at floor level.
pro series - distillation hood
This extra tall hood can be set on a low height table to maximize vertical space. This hood is especially helpful when you need the height of a floor mounted hood but also need the convenience of a traditional hood worksurface such as a distillation set up.
pro series - accessible hood
This all purpose fume hood is designed to meet ADA requirements for accessibility.
pro series - demonstration bench hood
Designed for instructor demonstrations this hood has a sash on both sides to permit full viewing by the instructor and observers.
pro series - perchloric acid hood
The perchloric acid hood is designed with a seamlessly welded and coved stainless steel liner with integral countertop. The hood has an internal wash-down system to prevent accumulation of dangerous oxidizers.
pro series - radio isotope hood
Designed to meet the stringent requirements of radioisotope applications, this hood is designed with a seamlessly welded and coved stainless steel liner with integral counter top.