products

RFV2 fume hoods

  • overview
  • details
  • options
  • resources
  • sustainability
  • families


high performance
energy savings

The RFV2 (Reduced Face Velocity) Series fume hood is specifically designed for high performance and energy efficiency.

  • Face velocities as low as 60 fpm with the sash full open
  • Flush sill with spill containment trough
  • Durable chain and sprocket sash system
  • Self-lowering sash that keeps the sash at 18” if raised above the set point
  • 34” viewing height
  • No mechanical baffle system or fans are needed, and no additional systems or moving parts to achieve high performance
  • VAV or CA
  • Extra deep hood


RFV2 Series Fume Hoods - New England Lab in Partnership with Mott ManufacturingFace Velocities

  • Designed for 50-80 fpm face velocity
  • Tested to ASHRAE-110 Guidelines
     

Downwardly Vectored Upper By-Pass

  • Prevents contaminated air build up behind the open sash
  • Supplementary mechanical fans or moveable baffles are not required
     

Sash Counterbalance System

  • Chain and sprocket sash
  • Durable for long lifespan
     

Self-Lowering Sash System

  • The sash latch temporarily secures the sash in the full open position for setup and tear down
  • When the latch is freed, the sash automatically returns to the operational position 
     

Full Viewing Sash

  • Provides a clear and unobstructed side-to-side view of the fume hood interior
  • 34” high viewing area
     

Low Profile Hinged Airfoil

  • Flush with the work surface
  • Spill trough is designed to provide secondary containment in the event a spill
  • Airfoil is hinged for easy cleaning
     

Chemical Resistant Liner

  • Standard fiberglass reinforced polyester liner
  • Additional liner materials available
     

Access Panels

  • Interior gasketed access panels 
  • Removable exterior side panels for ease of access to plumbing and electrical service fixtures
     

Duct Collar

  • Rectangular type 316 stainless steel collar
  • Optional transition to interface with the building ventilation system
     

Electrical Services

  • Two UL / CSA approved duplex receptacles were provided for 120-volt service
  • Built-in LED lighting and a corner post-mounted UL/CSA approved switch provided
  • UL 1805 Classified
     

Plumbing Services

  • The front post is pre-punched to accept up to four plumbing fixtures per side
  • Optional factory pre-plumbing of front-loaded remote or rod-driven fixtures 


* RFV2 Series fume hood is trademarked and produced by Mott Manufacturing.

 

Optional Automatic Sash Closing System
 

The electronic occupancy sensor system closes the sash automatically when not in use, or within a timed interval when the operator moves away from the fume hood.

 
 

 

Product Brochures

Title Size Download MyPortfolio
Mott - RFV2 Series Fume Hood 2.35 mb download [+]
NEL - RFV2 Series Fume Hood Brochure 1.34 mb download [+]

Product Specifications

Title Size Download MyPortfolio
Painted Steel Powder Coat Appendix 1 15 kb download [+]
RFV2 Fume Hood Specifications 40 kb download [+]

Product Manuals

Title Size Download MyPortfolio
Fume Hood User and Installation Product Manual 461 kb download [+]

Corporate Literature

Title Size Download MyPortfolio
Lab Fume Hood Selector Guide 745 kb download [+]

Catalog Sections

Title Size Download MyPortfolio
Mott Fume Hood Catalog Section P 7.02 mb download [+]
Mott Fume Hood Introduction Catalog Pages P1-P3 399 kb download [+]
Mott RFV2 Fume Hood Catalog Pages P16-P19 574 kb download [+]
Resource Thumbnail

Mott RFV2 High Efficiency Fume Hood

Our low flow fume hoods can result in considerable energy cost reduction and ensure operator safety.  Designed to operate from 60-100 feet per minute face velocities.  They have been tested as low as 50 feet per minute.

Our low volume option can result in considerable energy savings by reducing the sash opening size.

An Automatic Sash Operating System can be incorporated that lowers and/or rises automatically which can enhance safety and dramatically increase the efficiency of Variable Air Volume (VAV) fume hood systems.

Steel

Painted steel consists of 85% or greater recycled content:

  • 42% post consumer which can contribute to LEED 2.2 credit MR4.1 & M4.2
  • 27% pre-consumer which can contribute to LEED 2.2 credit MR4.1 & M4.2
  • Systems solutions that maximize mobility and adaptability creating a user friendly, long life-cycle laboratory.
  • Durable, high-quality surface protection with minimal waste and Zero VOC's.
  • Durability that meets and exceeds SEFA 8 performance standards, to provide an even longer product life cycle.


Stainless steel consists of 90% recycled content:

  • 80% post consumer which can contribute to LEED credit MR4
  • 20% pre-consumer which can contribute to LEED credit MR4
  • Durable, high-quality surface protection with minimal waste and Zero VOC's.
  • Durability that meets and exceeds SEFA 8 performance standards, to provide an even longer product life cycle.
rfv2 series - bench-mounted hood thumbnail

rfv2 series - bench-mounted hood

The high-performance bench-mounted fume hood has been factory tested to both standard and modified ASHRAE procedures at face velocities as low as 50 fpm.

rfv2 series - accessible hood thumbnail

rfv2 series - accessible hood

This high performance fume hood is designed to meet ADA requirements.

need it now?

Purchase laboratory furniture and accessories from our online store!

(888) 635-2949

new england lab | lab-tested furniture systems - View Our Complete Line of Casework, Cabinets, Adaptable Lab Furniture Systems, Fume Hoods and More
new england lab, lab-tested furniture systems, laboratory casework, adaptable furniture, casework, lab construction, lab design-build projects,quick ship,
New England Lab: lab-tested furniture systems - View Our Complete Line of Casework, Cabinets, Adaptable Lab Furniture Systems, Fume Hoods and More!